LWS & reg; Spesifikasi PCM Kanggo Paket Baterai Li-ion 25.9V ï¼7Sï¼ | |||
|
|||
Ora. | Item tes | Kriteria | |
1 | Tegangan | Tegangan pengisian | DC: 29.4V CC/CV |
Tegangan imbang tunggal |
4.2±0.025v |
||
2 |
saiki | Imbangan saiki kanggo sel siji |
42±5mA |
Konsumsi saiki |
â¤50μA |
||
Arus pangisian daya terus-terusan maksimal |
15A |
||
Maksimal terus-terusan Discharging saiki |
15A |
||
3 |
Over charge Protectionï¼¼(sel tunggal) |
Tegangan deteksi overcharge |
4.25±0.025V |
Swara wektu tundha deteksi daya |
500mSâ1500mS |
||
Tegangan release over charge kanggo sel tunggal |
4.1 ± 0.05V |
||
4 |
Proteksi over discharge (sel tunggal) |
Tegangan deteksi liwat discharge kanggo sel siji |
2.5V±0.062V |
Swara wektu tundha deteksi discharge |
10mSâ150mS |
||
Over discharge release voltase kanggo sel siji |
3.0±0.062V |
||
5 |
Swara pangayoman saiki |
Swara voltase deteksi saiki |
100±25mv |
Ngisi daya liwat deteksi saiki |
40±5A |
||
Wektu tundha deteksi |
50-600mS |
||
Kondisi release |
Cut beban, Recovery otomatis |
||
7 |
Resistance |
Sirkuit proteksiï¼¼MOSFETï¼ |
â¤20mΩ |
8 |
Suhu |
Kisaran Suhu Operasi |
-20ï½+60â |
Kisaran Suhu Panyimpenan |
-20ï½+65â |